...
Page Contents
Table of Contents | ||||||
---|---|---|---|---|---|---|
|
...
Introduction
This page demonstrates hoe to configure WinCan VX and WinCan Map for the best results while making 3D Measurements using iPek equipment.
...
WinCan VX makes a backup of the user data on the first launch each day, which is why it takes slightly longer to start up each morning. Where a new installation is made, these settings can be retrieved from the option in Tools → Backup → Restore → Restore from file.
...
WinCan VX User Settings
The WinCan VX User Settings are accessed from the Home → Settings menu option.
Don’t auto create laterals
...
By default, this setting is on, it should be turned off for this workflow.
...
This saves the need to explicitly click the Auto Create Laterals button in the Tools ribbon.
Section/Lateral Auto-naming
...
In many inspection standards in WinCan VX, the auto naming (how the asset ID of the section or lateral is constructed) is defined by the standard and is set in the template in VX. In these cases, the user cannot change the naming pattern and it does not matter what is set here.
...
Further down, we have the system default naming pattern which by default is ‘Date and time stamp’. This is not needed if the main naming pattern is set, but if the user wishes to not set a default naming pattern, then they should reset this option to ‘8 character random string’ to avoid problems where multiple laterals created by the auto-create lateral tool have the same ID when they are created by the computer all in the same second.
3D Measurement
...
Here, we must select the correct measurement device and hit the green tick to confirm.
For some devices, it is also necessary to click the ‘Select start direction’ checkbox, but not for all and not for iPek.
Auto Create Connections Plugin
...
It is important to set these controls so that when the laterals are auto created, the nodes have the correct naming patterns for the selected inspection standard.
The naming pattern - set as required. For German standards, there are 2 options:
DEU Isybau - Inspektionsrichtung - numbers the connection points and lateral upstream nodes numerically along the length of the inspection from the beginning, starting at 1.
DEU Isybau - Fliessrichtung - similar to a, but always in a downstream direction, regardless of the way that the inspection was carried out by the operator.
For the Isybau standard, this must be set to ‘Use connection type’. For all other standards, use the default option ‘Use node type’.
Set the default inspection direction for system created laterals. For 3D measurement, this will usually be upstream, but there are other workflows that also use this tool, where it would be normal to set it to downstream.
if the coordinates of both of the nodes connected to the lateral are known, then we can automatically assign their geometric length in either full 3D or XY plane only 2D. Full 3D works very well when you have excellent 3D geometric data, but it can also cause problems when the data is not so good, maybe where some nodes have good Z values and some have it not defined. Using the 2D length is a safer option, but maybe slightly less accurate. The 3D option will give more accurate results, but will give really wild results where the data is bad.
View Profile
In order to display the 3D Wizard for this workflow, we must set the VX main window view theme:
...
If the 3D Measurement panel is not visible, it can usually be reactivated by clicking on the ‘Show Hidden Windows’ button in the Views ribbon bar like this:
...
WinCan VX Project Tips
Setting the Coordinate System
When a new WinCan project is created, user can set the required coordinate system here before the first time WinCan Map is opened for the current project:
...