Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.






3D-Measurement of the Pipe Geometry with Geo-Sensors

Version: 2.4

Date: 17.08.2023

...

If either the hardware configuration or the the hardware itself is faulty, the measurement wizard will return a corresponding feed-back.

...

It is crucial for a reliable calculation of the 3D pipeline network, that you have entered valid data into all the corresponding altitude/depth fields of the section and node category:

  • Pipe depth in the upstream manhole (from cover to pipe bottom) (SECTION.OBJ_FromNodeDepth)

  • Pipe bottom altitude (above sea level) in the upstream manhole (SECTION.OBJ_FromNodeInvert)

  • Pipe depth in the downstream manhole (from cover to pipe bottom) (SECTION.OBJ_ToNodeDepth)

  • Pipe bottom altitude (above sea level) in the downstream manhole (SECTION.OBJ_ToNodeInvert)

  • Manhole cover altitude above sea level (Z-Coordinate) (NODE.OBJ_Shape_WKT_Z)

  • Depth of the upstream/downstream manhole (from cover to bottom) (NODE.OBJ_DepthToInvert)

  • Bottom altitude above sea level of the upstream/downstream manhole (NODE.OBJ_NodeInvert)

The sketch below illustrates the meaning of these fields:

...

Legend:

Green = values to be provided by engineers/water authorities

Brown = values to be measured by the operator or provided by engineers/water authorities

Blue = values to be measured by the operator

Red = values calculated by WinCanVX hitting the button Tools > Calculate Invert Levels

Running 3D measurement for main pipes

...