6.) Check the functionality of the VITEC-board running the livewire test application: C:\Program Files(x86)\CDLab\Drivers\TestApp\Vitec\Vitec Test App.exe

...

Recommended settings: Input=Composite 3; Standard=PAL; VideoPreview Mode=DirectDraw

7.) Check all the cable connections. The devices must be linked together exactly as shown in the sketch below:

...

8.) Make sure the power supply is stable!

9.) Check the communication between the text generator from iPEK (DE03SW, DE08CO/CVO or DCX/Vision Control) and the computer within the OSD-Settings dialogue:

...

10.) First check if the crawler has got a built-in inclination sensor. Press Shift-Ctrl-1 to turn on the display of the inclination percentage value. Lift the crawler on one side to see if the sensor works correctly.

11.) Run the file C:\Program Files (x86)\CDLab\Assemblies\MultiUSBConfig.exe as Administrator:

...

12.) The MultiUSB configuration panel opens and allows you to check the device mode (1), the COM-port (2) the input channel for inclination (3) as well as the distance unit (4):