Instructions
Specification
Before GIS-data can be transferred into WinCanVX, each GIS field needs to be mapped or assigned manually to the corresponding WinCan field. The most important section/manhole fields are listed below
- OBJ_Key -> Section/Manhole Name (unique name to identify the section/manhole)
- OBJ_Length -> Length of the section (distance from Upstream Manhole to Downstream Manhole)
- OBJ_DepthToInvert -> Depth of the manhole (distance from cover to bench/channel)
- OBJ_City -> Name of the City/Town where the section/manhole is located
- OBJ_Street -> Name of the Street where the section/manhole is located
- nodeFromKey -> Name of the Upstream Manhole
- nodeToKey -> Name of the Downstream Manhole
- OBJ_Shape -> Shape of the pipe (circular, rectangular, egg-shaped etc.)
- OBJ_Size1 -> Diameter/Height of the pipe [mm] / [inch]
- OBJ_Size2 -> Width of the pipe [mm] / [inch]
- OBJ_Material -> Material of the pipe (concrete, steel etc.)
- OBJ_SectionType -> Type of section (waste water, stormwater, mixed water)
- OBJ_Usage -> Type of section (replaces OBJ_SectionType in some standards)
- OBJ_WasteWaterType -> Type of section (replaces OBJ_SectionType in some standards)