Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Release notes - WinCan VX - 1.2023.15.1

Page Contents

Table of Contents
minLevel1
maxLevel4
exclude(Page Contents|Abstract|Author).*

...

New Requests

  • WVX-7637 CH-Interlis Import/Export: New data model 2020

  • WVX-8505 Cyclic upload of the project to the WEB

  • WVX-8524 Option to Include External Docs in Print

  • WVX-8733 VSA-2019 Total Score Calculation Update

  • WVX-8755 New Cleaning Data Entry System Needed

  • WVX-8762 VX - Cityworks - Error Handling

  • WVX-8764 VX - Cityworks - 15.8 Upgrades - Handle media attachments

  • WVX-8952 [Printing] New Z profile Report

  • WVX-9021 New Option to Auto Create Lateral Against Inspection

  • WVX-9033 [3D Application] Option to Reload Project

  • WVX-9078 Investigation - Vivax Locator: Z coordinate correction with GeoTif

  • WVX-9086 Enterprise - Add the ability to search by master project name

  • WVX-9161 OSD Shenzhen Singa: Add setting distance unit

  • WVX-9213 Shenzen Singa OSD: protocol changes

...

3D New Requests

  • IP-22 [DCX5000] Wizard Option to Define Vertical Measurement

  • IP-160 Option in VX to Delete 3D Measurements

  • IP-192 Check iPEK CVO Interface Version V1.13 for 3D support

  • IP-193 Add Licensing of iPEK devices

  • IP-194 Add 3D Status Symbol in DCX5000 Dashboard

  • IP-195 Set Inclination offset of PTP50 camera, if Mugel is used

  • IP-216 Allow user to select what to do with node when measurement is abandoned

  • IP-234 Some texts are not translated

...

Bug Fixes

  • WVX-9123 LightViewer starts with an error message

  • WVX-9159 It's not possible to print any Node report

  • WVX-9160 Swiss VSA 2019 Standard - Error when adding some observations

  • WVX-9271 RC 15.1 Import Geodatabase Doesn't Work Anymore

  • WVX-9279 [ReleaseTest] 3D Measurement shows "Start node has no coordinates" while the node had been placed.

  • WVX-9285 [ReleaseTest] Auto Create Connections creates two inspections for each created node.

  • WVX-9286 [ReleaseTest] Auto Create Connections works wrong if an existing lateral has upper node of CON type.

  • WVX-9288 [ReleaseTest] InvalidOperationException when clicked NEXT button after selecting "Manually plot node in Map"

  • WVX-9291 v8-VX Conversion Doesn't Create New Node Inspection Records

  • WVX-9303 SIA-405: Coordinates are not correctly imported anymore

  • WVX-8292 Hansen Export

  • WVX-8457 [Map] Selection shape is re-rendered after zoom/pan

  • WVX-8518 VX crashes when trying to close it when Miraculix Editor window is open

  • WVX-8640 Rehab Catalogue Editor Does Not Support all Languages or Currencies

  • WVX-8657 Modifying sewer elements in WO - additional WO processes in VX

  • WVX-8658 SoftwareOSD: OSD objects are shown if they are switched off

  • WVX-8668 Error in text display; range of local defect (e.g. BCBE) not always completely displayed

  • WVX-8670 Inspected manholes not highlighted in the corresponding color

  • WVX-8687 360 videos upside down

  • WVX-8688 Photos taken from 360 videos are not correct

  • WVX-8696 [Template Editor] Not Possible to Move Lines Anymore

  • WVX-8704 Created Files Not Added to DOCU Table

  • WVX-8722 Deactivate/Change License buttons missing

  • WVX-8737 Manhole Tab can't be opened for Re-imported RibX project

  • WVX-8746 Buttons on the bottom section not working properly?

  • WVX-8752 V14.1 - Normal Viewer does not start sometimes

  • WVX-8760 Create new project wizard form height needs adjustment

  • WVX-8770 Export Error for Isybau XML, Material for In- and Outlets

  • WVX-8772 Adding INFLOW or OUTFLOW entry observation creates the entry with UNKNOWN flow direction

  • WVX-8781 Issue with GIS import into existing project

  • WVX-8784 Auto Create Laterals Upstream Node Type Doesn't Work

  • WVX-8826 DataExchange - MACP6 - ipf are not being attached as scans

  • WVX-8828 After Load the Database from VC500 into VX - Error in 3D

  • WVX-8829 Exception if OBJ_Shape_WKT of a section has only one coordinate

  • WVX-8837 [Technical] Update jQuery to mitigate risk of exploits in VX

  • WVX-8842 Copy Function for Section, Laterals and Manholes shows not all Data

  • WVX-8880 Map: Vivax error

  • WVX-8923 3D Application Plots the Manhole at the Wrong Coordinates

  • WVX-8930 Z Profile View Problems

  • WVX-8959 No inclination values ​​Ibos Boss 100 Boss 150 CamBoss 4 PAL

  • WVX-8967 [3D measurement] Measurement gets only (1,2,3) points and throws exception

  • WVX-8970 When adding a starting observation, a popup asking whether to reset the counter is not displayed.

  • WVX-8984 The new node is drawn incorrectly in 3D.

  • WVX-8986 VX crashed during a forward measurement from downstream with upstream inspection of a lateral

  • WVX-8998 Node Edit Window Opens at the Last User Position

  • WVX-8999 Pop Ups Opening in the Wrong Place Onscreen

  • WVX-9012 ProTouch daily job is throwing null ref exception but it looks like catalogs are committed anyway to their repo

  • WVX-9023 DataExchange - MACP7 - Connection pipe number changing on import

  • WVX-9025 BEDDSS Export Problem

  • WVX-9027 DataExchange- MACP7 - Import/Export should not add default values when empty

  • WVX-9030 [Map] Observation Layer Missing Fileds for Display

  • WVX-9031 Scoring - MACP7 - Frame Offset Distance (structural) Rating wrong value

  • WVX-9032 Node Templates Should Not be Set On Install of Map

  • WVX-9034 Views -> Save As Does not Behave as Expected

  • WVX-9041 Cannot Manually Add an Existing Lateral to a new Code in a New Inspection

  • WVX-9044 DataExchange - MACP6 - Import/Export missing values

  • WVX-9045 Connector Node Linked to Wrong Observation

  • WVX-9046 Auto Create Lateral Tool Does not add OBJ_Unit to CON Nodes

  • WVX-9049 Map Select All when No Layer Select Throws Exception

  • WVX-9051 Inspection Grid Crash

  • WVX-9058 [SDK.GIS] Tests are not working on Release config on build server

  • WVX-9060 Latvia NZPIM scoring, has no object scoring results

  • WVX-9061 CDLAB.WinCan.MediaRenaming - Building a solution fails

  • WVX-9064 Cannot change node coords when depth to invert is not set. 3D does not plot nodes without chamber filled

  • WVX-9067 Map is Not Showing Sections

  • WVX-9070 Fix - Unable to Print from SQL Server

  • WVX-9072 Whilst using a filter in VX followed by media distribution not all folders are exported (Docu, video and pictures)

  • WVX-9081 Wrong Translations in WinCan VX and Web Reports

  • WVX-9082 Missing Geometry Value (RAP) in Data Export for Isybau Sections and Manholes

  • WVX-9087 License kept activated despite it has been deactivated in WIS

  • WVX-9096 MACP- Template should change base on field Inspection Level

  • WVX-9098 MACP- Ratings should revalidate after saving MH parts

  • WVX-9099 WinCan OSD

  • WVX-9116 DataExchange- MACP6 - Import/Export should not add default values when empty

  • WVX-9118 [Release Tests] Scan Explorer takes wrong scan path

  • WVX-9119 Switching sections is extremely slow due to inefficient OsdTextBuilder implementation

  • WVX-9122 [Release Test][DDMS] Map didn't show an automatically created lateral immediately - Reload project was needed

  • WVX-9124 Imported Data Messed up on Multipoint Isybau 2006

  • WVX-9125 [Release Test] Service Host - merge failed "Line 1160: Object reference not set to an instance of an object."

  • WVX-9127 [MERGER] AI Inspections not merged when merging a Project to Enterprise Master Project

  • WVX-9134 [Map] Exception after map reinitialization when snapping is on

  • WVX-9136 Buttons in Photo/Video window do not work after creating lateral in lateral

  • WVX-9138 [Release Test] SQL based project -> Printing the report -> "The ObjectContext instance has been disposed…"

  • WVX-9139 [Release Test] A thread exception during report printing of a SQL project.

  • WVX-9150 Error in Map when changing coordinate system of layer

  • WVX-9151 [3D measurement] Open project with inclination data only, crashes with a ArgumentNullException.

  • WVX-9152 [IBAK] Lateral measurement (forward, from lower node) starts going in wrong direction.

  • WVX-9157 Problem with creating new project

  • WVX-9158 Applicaton thread exception: System.Exception: Assembly HarfBuzzSharp - two scenarios

  • WVX-9163 MOATAv4 export not working in Wincan v15.0.6

  • WVX-9165 The new country only appears after a clean installation

  • WVX-9166 System.InvalidOperationException on video recording stop (Video Device is Elecard)

  • WVX-9169 WinCan 3D module (WinCan3DVX.exe) crashes just after showing "Starting WinCan 3d"

  • WVX-9188 New Merger, merging into New Project, FOREIGN KEY constraint failed.

  • WVX-9199 Map VX, error when trying to Draw point without layer selected

  • WVX-9205 No Node coordinate in the Node report, Multipoint problem

  • WVX-9206 [MAP] Exception when you want to draw a line and close wizard before end

  • WVX-9224 SDK.GIS Inspection calculation exception

  • WVX-9284 [Web] use nologout flag to get longer token which cannot be invalidated by logging to browser with same credentials

  • WVX-9292 [ReleaseTest] Start of Normal Distribution lasts for over 15 minutes (so I eventually aborted it).

...

3D Bug Fixes

  • IP-24 Map Show Measurement Tool Updates

  • IP-26 Remove Z Angle Option from Wizard for iPek 3D Devices

  • IP-30 Creating an Observation Causes WinCan Marker (Blue Dot) to be Moved During 3D Measurement

  • IP-104 Wrong Image in Wizard for Forwards Measurement from Upper Node

  • IP-105 Update Wizard Images

  • IP-118 WinCan3D: Not all setting for visible layers are saved

  • IP-120 Map throws exception when connecting to wincan and legend is blank afterwards

  • IP-132 Abandoned (BDC) Codes not Correctly Handled

  • IP-138 3D Measurement Lateral is Not Rotate/Scaled in Z Direction After Measurement

  • IP-140 Wrong Graphic When Lateral Downstream Node is a NOD

  • IP-141 Inspection is Displayed When there isn't One

  • IP-144 3D Application Cannot Work with Large Projects

  • IP-145 Cancelled 3D Measurement Visible in Map and in the 3D Module

  • IP-146 Modify Start Direction of Backwards Measurement Directly After Forwards when Node Location is Unknown

  • IP-147 Measurement Against Inspection Direction Suggests Wrong Direction

  • IP-150 RAP Vertice Has Been Removed from Lateral WKT

  • IP-151 Set Shape and Offset Prompts Not Needed in Some Situations

  • IP-166 Bad Results if the CON is not at the Same Coordinates as the Obs Code

  • IP-173 Unable to Edit Object Shapes More than Once or After Reset Transformation

  • IP-176 Inspection and Observations in wrong place after Rotate & Scale

  • IP-180 Existing Laterals get Messed Up when Adding New

  • IP-182 Red Arrow is Still Incorrect when Measuring Against the Inspection

  • IP-183 Different Start direction is sent when backward measurement in a lateral is started

  • IP-187 Before ending the forward measurement of a lateral the question " Do you want to make a backward measurement ?" pops up.

  • IP-190 Start position of lateral is not at RAP if main pipe has bends

  • IP-196 After measurement section is not rotated and scaled

  • IP-208 WinCan3DVX.exe - "Rendering shapes…" pop-up doesn't disappear.

  • IP-209 Name of section in measurement wizard is always "label3"

  • IP-210 Status text is incorrect when measurement is in progress

  • IP-211 When width of pipe is specified, lateral forward measurement starts from AP

  • IP-212 Measurement does not work when Upper Node is a CON

  • IP-214 When doing bwrd measurement after fwd of lateral with insertion in upper node, the start direction is wrong

  • IP-223 Offset is not applied to the section after lateral measurement from main pipe so inspection starts from AP not RAP

  • IP-225 abandon measurement and select plot manhole automatically. Then node is at wrong place

...

Back to Top

Back to Releases