Diameter Measurement with Laser Cameras
Version 2.2
Date: 27.10.2022
Table of Contents |
---|
Diameter measurement with iPEK, RICO or RIEZLER cameras
This measuring system consists of a PAN & TILT camera with two built-in lasers sources producing beams that are parallel to each other and symmetric to the view direction. Over the known vertical view angle (or field of view) you can calculate the distance of the camera to the laser dots. If you look perpendicular to the pipe surface and rotate the camera head 360° around the pipe axis a cross section profile of the pipe is going to be created.
...
iPEK; SVC75
iPEK; SVC100
iPEK; RCX90
iPEK; RCX90 new
iPEK; RCX90 HD
iPEK; PTC50
iPEK; PTP70II
RICO; SR50
RICO; SR100
RICO; SR100 RPP
RICO; SR100 PLUS
RICO; SR100 PLUS V
RIEZLER; RSK-60100
RIEZLER; RCK-115
Configuration in WinCan VX
Hit the command Home > Programm Information and make sure the following features are activated for your license:
...
Info |
---|
In case of working with an iPEK camera system the user will have to push the corresponding start button on the iPEK control unit. This is going to activate the laser dots, the camera head automatically rotates and the picture luminosity is reduced to 0%. |
In case of working with camera systems from RICO or RIEZLER please contact the corresponding manufacturer for the required hardware control steps.
Measuring procedure
Make sure the camera is switched on and hit the button Parallel-Laser in the OSD-Panel to launch the measurement:
...
The message Too many spots will warn you immediately if ever the image is too bright and the laser dots are not flashing up distinctly.
...
Switch the light off, click on the button Start Scan and the camera starts measuring the diameter:
Once the light is switched off and the image is dark enough the text Waiting (2) will be displayed, otherwise the text Waiting (1) is shown:
...
The button Save Picture allows the user to save the displayed result as a picture in the JPEG format.
Diameter measurement with RAUSCH cameras
This measuring system consists of a PAN & TILT camera with two built-in lasers sources producing beams that are parallel to each other and symmetric to the view direction. Over the known vertical view angle (or field of view) you can calculate the distance of the camera to the laser dots. If you look perpendicular to the pipe surface and rotate the camera head 360° around the pipe axis a cross section profile of the pipe is going to be created.
...
RAUSCH; KS60 D
RAUSCH; KS60 HD
RAUSCH; KS135
RAUSCH, KS135 HD
Configuration in WinCan VX
Hit the command Home > Programm Information and make sure the following features are activated for your license:
...
Please contact the camera manufacturer RAUSCH regarding the required hardware control steps that may strongly depend on the camera type you currently use.
Measuring procedure
Make sure the camera is switched on and hit the button Parallel-Laser in the OSD-Panel to launch the measurement:
...
The button Save Picture allows the user to save the displayed result as a picture in the JPEG format.
Diameter measurement with IBAK cameras
In case of working with an IBAK camera system the user will have to push the corresponding start button located in the horizontal/vertical tool bar of the virtual text generator SoftControl.
Program Settings
Launch WinCanVX, hit the command Home > Settings > OSD (1)and select the device IBAK-SoftControl (3). Hitting the gear icon right to the device list box is opening another dialog with further options.
...