Diameter Measurement with Laser Cameras

Version 2.2

Date: 27.10.2022

Table of Contents

Diameter measurement with iPEK, RICO or RIEZLER cameras

This measuring system consists of a PAN & TILT camera with two built-in lasers sources producing beams that are parallel to each other and symmetric to the view direction. Over the known vertical view angle (or field of view) you can calculate the distance of the camera to the laser dots. If you look perpendicular to the pipe surface and rotate the camera head 360° around the pipe axis a cross section profile of the pipe is going to be created.

...

  • iPEK; SVC75

  • iPEK; SVC100

  • iPEK; RCX90

  • iPEK; RCX90 new

  • iPEK; RCX90 HD

  • iPEK; PTC50

  • iPEK; PTP70II

  • RICO; SR50

  • RICO; SR100

  • RICO; SR100 RPP

  • RICO; SR100 PLUS

  • RICO; SR100 PLUS V

  • RIEZLER; RSK-60100

  • RIEZLER; RCK-115

Configuration in WinCan VX

Hit the command Home > Programm Information and make sure the following features are activated for your license:

...

Info

In case of working with an iPEK camera system the user will have to push the corresponding start button on the iPEK control unit. This is going to activate the laser dots, the camera head automatically rotates and the picture luminosity is reduced to 0%.

In case of working with camera systems from RICO or RIEZLER please contact the corresponding manufacturer for the required hardware control steps.

Measuring procedure

Make sure the camera is switched on and hit the button Parallel-Laser in the OSD-Panel to launch the measurement:

...

The message Too many spots will warn you immediately if ever the image is too bright and the laser dots are not flashing up distinctly.

...

Switch the light off, click on the button Start Scan and the camera starts measuring the diameter:

Once the light is switched off and the image is dark enough the text Waiting (2) will be displayed, otherwise the text Waiting (1) is shown:

...

The button Save Picture allows the user to save the displayed result as a picture in the JPEG format.

Diameter measurement with RAUSCH cameras

This measuring system consists of a PAN & TILT camera with two built-in lasers sources producing beams that are parallel to each other and symmetric to the view direction. Over the known vertical view angle (or field of view) you can calculate the distance of the camera to the laser dots. If you look perpendicular to the pipe surface and rotate the camera head 360° around the pipe axis a cross section profile of the pipe is going to be created.

...

  • RAUSCH; KS60 D

  • RAUSCH; KS60 HD

  • RAUSCH; KS135

  • RAUSCH, KS135 HD

Configuration in WinCan VX

Hit the command Home > Programm Information and make sure the following features are activated for your license:

...

Please contact the camera manufacturer RAUSCH regarding the required hardware control steps that may strongly depend on the camera type you currently use.

Measuring procedure

Make sure the camera is switched on and hit the button Parallel-Laser in the OSD-Panel to launch the measurement:

...

The button Save Picture allows the user to save the displayed result as a picture in the JPEG format.

Diameter measurement with IBAK cameras

In case of working with an IBAK camera system the user will have to push the corresponding start button located in the horizontal/vertical tool bar of the virtual text generator SoftControl.

Program Settings