Before GIS-data can be transferred into WinCanVX, each GIS field needs to be mapped or assigned manually to the corresponding WinCan field.
This article describes which field mappings have to be created so sections and manholes can be transfered to from WinCan Map to WinCan VX.

Instructions

Step-by-step instructions

  1. Select WinCan Map Feldzuordnung bearbeiten auswählen.

  2. Edit WinCan mapping

  3. The most important section/manhole fields are listed below..

OBJ_Key

Section/Manhole Name (unique name to identify the section/manhole)

OBJ_Length

Length of the section (distance from Upstream Manhole to Downstream Manhole)

nodeFromKey

Name of the Upstream Manhole

nodeToKey

Name of the Downstream Manhole

OBJ_DepthToInvert

Depth of the manhole (distance from cover to bench/channel)

OBJ_City

Name of the City/Town where the section/manhole is located

OBJ_Street

Name of the Street where the section/manhole is located

OBJ_Shape

Shape of the pipe (circular, rectangular, egg-shaped etc.)

OBJ_Size1

Diameter/Height of the pipe [mm] / [inch]

OBJ_Size2

Width of the pipe [mm] / [inch]

OBJ_Material

Material of the pipe (concrete, steel etc.)

OBJ_SectionType

Type of section (waste water, stormwater, mixed water)

OBJ_Usage

Type of section (replaces OBJ_SectionType in some standards)

OBJ_WasteWaterType

Type of section (replaces OBJ_SectionType in some standards)

The field OBJ_Key is mandatory