Denmark Updates
Abstract
This document outlines the issues raised for fix during a visit to Denmark 16th - 19th January 2024.
Author
Steve Peregrine BEng Hons, Senior Technical Manager
Contents
Items Reported and Outcomes
The following is the list of fixes request by C-TV and JKL during Steve’s visit to Denmark, 16th-19th January 2024, working with Patrik Berg fro Dansk Kloak TV and Morten Tjørnelund from JKL Teknik.
Item No. | Source | Issue | Outcome |
---|---|---|---|
1. | JKL and C-TV | On PDF, the inlets/outlets table needs to display the linked code OBS_SortOrder. Obs Nr. and on the Obs table, need to display the inlet/outlet number. | Done in VX v15.2. Ready for test. |
2. | JKL and C-TV | <RapporttypeKode> tag in xml export should be:
| |
3. | JKL and C-TV | Data exchange Fysik Indeks <FI></FI> tag missing in all export files inside the <TVInspektion> tag - taken from STA_HighestGrade | |
4. | C-TV | INS_RapportNumber in manholes not populating from autonaming. | |
5. | C-TV | Add *-INS_SortOrder to DanDas inspection autonaming | Done in VX v15.2. Ready for test. |
6. | C-TV | Inspection autonaming only works on header save, so you have to open it, close it and open it again to see the value. Means also it is not updated when we make combined inspections. Should be automatic on page load or virtual etc. | |
7. | C-TV | Combined report must show the inspection shape/size/material fields from each inspection at each end and in the correct order. Currently only shows for the starting end. | |
8. | C-TV | Remove node reference from code S3 in section catalogues. | Done in VX v15.2. Ready for test. |
9. | C-TV | Remove Material, Mat BST, Shape, DIM, DIM BST from detail_s, and use inspection fields but this needs a data exchange update. | |
10. | C-TV | Section catalogue auto photo on all PH, PB, OS and OP codes. | Will not do, customer request only. No requirement in the standard for mandatory photo, unless advised otherwise. |
11. | C-TV | <AntalDok> tag in xml should not include scan count, but should include attached document count. Nodes only. All file names must be included in the <BRDokumentItems> tag. | |
12. | C-TV | Antal Dok (Nodes) is not printing a value on PDF, only zero. I slinked to item above. NodeInspectionHeader.V_INS_MediaCount NodeInspectionHeader.V_INS_PhotoCount + NodeInspectionHeader.V_INS_VideoCount. | Discussed with dev team. It works in L&L Editor but not in the printed PDF. Bug reported for fix. |
13. | JKL | Lateral printing - show OBS_Distance. Make a new line in the lateral data at the bottom of the page. Add the Stik Urref, the OBS_Distance and the Ur6 data field. | Done in VX v15.2. Ready for test. |
14. | C-TV | Can we copy paste inspection autonaming pattern to video and vica versa? Would be useful. | No, the section/node patterns have restrictions that the inspection patterns do not have. |
15. | JKL and C-TV | Make PDF naming preset the same as for videos. | Done in VX v15.2. Ready for test. Note - there are some limitations to this, maybe some quick training is needed. It only truly works for inspection level documents at print, not section level. |
16. | JKL and C-TV | Renaming at export - where is section naming option, and need to rename the whole file, not just the part at the end. Applies only to the 3 whole export files. Must validate duplicate names and not allow to proceed. The filename must also be inside the <Tekstfil> tag. | |
17. | JKL | Update all BST lists for 2.5 and 2.6 to the attached files in catalogues and templates. Note that for inlets/outlets, the manhole lists must be used, even though they are pipes. | Done in VX v15.2. Ready for test. |
18. | C-TV | VX allows 30 characters per node ID, but the iBak OSD only displays 20: | There is an option in OSD user settings here to modify the number of characters per line, but adjusting it may cause unwanted side-effects: The cleaner solution would be to go to the OSD configuration settings and put the upstream and downstream manhole IDs on separate lines, like this: Â |
19. | C-TV | The observation counters in the project summary report include observations from combined inspections and the inspected length values in the profile report include lengths from combined inspections, meaning they have the wrong values. They should not include combined inspections because they have already been counted in the original inspections. Affects all territories. | |
20. | C-TV | Node character limit is 30 characters. The auto create lateral tools can make node IDs longer than this. Need a pop up warning if this happens and also validate the xml export and block if any nodes. Affects all territories. | |
21. | C-TV | Value transfer to laterals. When user creates laterals, the new lateral should value transfer from the last created lateral for material, size, shape, material BST and size BST. Also auto-create. Test in a clean project. What if there are no laterals already created? Question asked to dev team. | WVX-9400 created for investigation and update. |
22. | JKL | Export nothing if not inspected (i.e. no observation codes). Export nodes only if INS_AbortReason is not null or inspection has observation codes. Also the same for printing. | |
23. | JKL | OS and OP codes - need to have inlet/outlet option and create inlet/outlet. | Done in VX v15.2. Ready for test. |
24. | JKL | Koordinat System and Kote System are mandatory in the manhole XML, optional in section/lateral. Update data validation files to give error. Export for sections/laterals if specified. Inside the headline group. PRJ_SystemCoordinate and PRJ_CoordSys. Since we always export all 3 main files, this makes it mandatory for all exports. | Included in WVX-9386 |
25. | JKL | <BroendKode> not exprted from OBJ_NodeType. Add before the <BroendformKode> tag. | Included in WVX-9386 |
26. | JKL | On inlets/outlets, NOE_Shape must be a simple list so that the letter code exports to xml file. | Done in VX v15.2. Ready for test. |
27. | JKL | In node xml, tag <ObsKategori> should only contain the code group and dashes should be null | Included in WVX-9386 |
28. | JKL | Lateral - field V_OBJ_MainLine gives OBJ_Key of the parent section, but we need the OBJ_PLRSuffix of the parent line. New virtual field needed. Possibly also needs a printing fix. Export is Ok | |
29. | JKL | The 3 virtual fields for laterals need to be writable and stored. User can make a lateral that is not connected to a section. Can make a project with only laterals and no sections, so they need to be able to complete these fields. | Included in WVX-9398 |
30. | C-TV | Value transfer section to node doesn't work on job number, operator, van etc (i.e. not natural database fields) Investigate and test. | WVX-9400 created for investigation and update. |
31. | JKL | Export option for creating section/lateral/node export always makes all. User option is not considered. | |
32. | JKL | Export manhole files into sub folder 'Broendrapport XML' instead of the main directory. All section, lateral and combined exports in the same place (like v8). | |
33. | JKL | Import xml doesn't work. | |
34. | JKL | MÃ¥ling/Maal - must be integer, max 10 digits, range 0 - 9999999999, no units at all times in node and section catalogues | Done in VX v15.2. Ready for test. |
Work Items
Please see below the relevant work items which are already in place in Jira and at various stages of development. All items are included in the Epic WVX-9385:
All work items including included in the DDMS Epic WVX-9385:
Team Members
@Stefan Bregy @Martin Hien