v18.2 Release Notes - 19 March 2026
This release focuses on stability, standards support, and Spirallo reliability, delivering multiple fixes across core VX workflows.
Significant improvements were made in ISYBAU data exchange and 3D workflows, addressing import and export reliability issues and improving correctness for geometry, activity types, and XML handling. At the same time, NASSCO v8 PACP export support was fixed, and the standard was updated with the latest validator DLL.
A major part of this release targets Spirallo, where several critical issues related to licensing, video processing, measurements, reporting, and 3D interaction were resolved. These fixes improve measurment accuracy as well as the day‑to‑day usability of the module.
In addition, multiple bug fixes improve overall stability in printing, GIS mapping, device integrations, cloud communication, and project handling. Ongoing technical improvements prepare VX for upcoming UI and framework changes, including DevExpress‑related refactoring and configuration handling.
Looking ahead, version 18.3 is planned for Apr 21, 2026
Full list of items delivered within v18.2 below:
🐞 Bugfix
WVX-11651 – Word splitting on printed reports - critical bug fix
WVX-11757 – Cannot open participants in custom template
WVX-11457 – GIS fields mapping
WVX-11415 – Integration issue with Riezler‑RiVision OSD device via RS232/USB
WVX-11411 – Loss of project list
WVX-11326 – AWS locally: use base URL from WIS and Authorization Code Flow
WVX-10986 – DigiSewer: potential inclination graph issue
🧭 ISYBAU Data Exchange & 3D
WVX-11773 – Import ISYBAU 2013 test file fails (release tests)
WVX-11712 – Import issue when HP is available for ISYBAU XML
WVX-11698 – OBJ_ActivityType function not working correctly
WVX-11663 – ISYBAU export: geometry not exported for new node with SMP, DMP and depth
🌀 Spirallo
WVX-11761 – Update Spirallo in Master VX installer
WVX-11725 – Cannot run TOF Spirallo report
WVX-11714 – Spirallo failure on Talha project
WVX-11697 – Spirallo videos cannot be processed
WVX-11683 – Spirallo failed error
WVX-11674 – LaserScan license defaults to Spirallo and stops working
WVX-11669 – Laser Scan crashes when interacting with 3D view window
WVX-11658 – Recorded video file size does not increase
WVX-11626 – Spirallo image size calculation fails
WVX-11625 – Spirallo measurement blocked due to license issue
📐 Standards & Compliance
WVX-11666 – Clone JSWA_CUSTOM to JAPAN_WINCAN standard
WVX-11772 – NASSCO 8 pipe (PACP) export does not work
WVX-11699 – NASSCO validator DLL update to version 1.20.0
⚙️ Technical
WVX-11579 – DevExpress prep: SearchAndReplaceDialog
WVX-11578 – DevExpress prep: ReportGeneratorDialog
WVX-11577 – DevExpress prep: ProjectDocumentsBrowserDialog
WVX-11576 – DevExpress prep: DeleteMediaDialog
WVX-10750 – Investigate config object serialization