Digisewer Test evironment
To do this test setup you require items
Vitec VM4-C7 or VM4-C8
Null Modem Cable, not a Link Cable
2 Comports, 2 USB Serial adapter
Video source
OSD_Simulator.exe
Instructions
- Install the 2 Comports
Connect the 2 USB COM with the Null Modem Cable - Run the OSD Simulator and click on the button open config folder
- Open the OSD __Simulator.ini
And the following line EnableAllDevices=1 in this ini file - This entry will activate new function for the OSD Simulator
Then click on the Start button. - The select the iPEK DE08
and 1 of the Comports. In this case the selected COM is 3 - Run the MultiUSBConfig.exe
select OSD Only and select the comport. Because we used the COM3 with the OSD simulator we have to select the remaining COM4.
Save the changes - Start VX and configure the OSD "DE08CO"
Click the Test button to verify your configuration.
If everything was done correctly.The connection will turn green.
Now you are ready to use the Digisewer test environment.
Related articles