Most of the descriptions included in this manual up to this point have been designed to help the guys on site in the CCTV truck work as effectively as possible to maintain efficiency and profitability during the works.

...

It is essential the section Using WinCan VX with WinCan Map is considered in detail before working through this section.

...

Plotting Uncharted Assets

There will often be instances where you need to create objects (pipes and nodes) in WinCan VX that do not exist in the loaded data, either because there simply is no existing data on the system for the stretch of highway that you are working on or because you because there is data, but you have located uncharted assets.

...

First node plotted.

...

All finished.

...

Connecting a Lateral to a Main

Now, let’s extend the previous inspections so that it has some connection code in the inspection data at 25m (at 2 o’clock) and 32m (at 10 o’clock), and there are some gullies on each side of the central reserve plotted in the data, like this:

...

The icon shows you that a lateral is tied in here and double clicking on this link will take you straight to that lateral in the other grid view, and there is also a button with an ‘up’ triangle arrow in the lateral grid view which will bring you bak to the section that this lateral is linked to.

Tip

Advice - although this technique does not really appear to make a great difference to the data and the drainage network design, it’s power is that because the laterals and the section are now tied together, when we introduce the GIS data at a future point and in that data, the 2 gullies and the 2 catchpits now have new coordinates in 3 dimensions (so far, everything has had no Z value here), the shape geometry of the sections and laterals will be modified and the coordinates of the connector nodes will be replotted, so everything will stay tied together when the new positions are introduced.

If you do not make the lateral links, then the lateral pipes will become detached from the section when the new positions are brought in and it becomes very (unnecessarily) time consuming to re-attach them all.

There are some additional techniques for joining objects together using the snapping tools in WinCan Map, but these are more usually used by data processing teams, and will be described in Snapping Objects in WinCan Map.

...

Creating New Inspections of Existing Assets

Using the techniques described in Using WinCan VX with WinCan Map, we can quickly and effectively navigate between objects in WinCan VX and WinCan Map without the need for manual searching.

...

The ‘New Inspection’ buttons.

Note

Warning - the big mistake that people make here is working the same way that they did in WinCan v7 (and most likely in WinCan v8).

In these versions of WinCan, when you wanted to create a second (or more) inspection of an asset, you simply created a new object with the same details as the first one in the grid view and then carried out a new inspection.

!!! THIS MUST NOT HAPPEN IN WINCAN VX !!!

See additional info in the next section.

To create a new inspection of the object, you simply have to click on one of the two buttons shown in the image above. Hovering your mouse over the buttons will tell you what they do:

...

If you subsequently need to abandon this inspection for any reason, then do not worry about the END code that has been automatically added for you. This will be removed when you complete the abandoned code.

...

Avoiding Creating Duplicate Objects

Note

In Warning - in WinCan VX, a line in the grid view is a pipe or other object. It is NOT an inspection. A section can have as many inspections as you like and from either end.

The column on the right hand side direction of the grid view with the two magnifying glasses at the top CCTV survey has no relationship with the section. The section (or lateral) is just a pipe in the ground.

The column on the right hand side of the grid view with the two magnifying glasses at the top shows you how many inspections there are of this object, and if the field is blank, then there is 1 or no inspections of the asset.

If you ignore all of the above advice and carry on regardless with creating duplicate assets, then when you enter the header data and click on the save button at the bottom, you will be prompted with this pop up warning:

...

Warning 1.

This is the first warning that you will receive and it does not take ant consideration for the inspection direction, so just because the last inspection was downstream and this one is upstream, this makes no difference at all to the fact that you have created a duplicate pipe with the same Supplier’s Reference and the same upstream and downstream nodes.

If you wish, you can click ‘Yes’ and you can proceed, but it is NOT recommended. You will now be prompted with this pop up message:

...

Warning 2.

This is your second chance to undo the problems that you are about to create in the data. You can again click on ‘Yes’ if you wish, but this is NOT RECOMMENDED even more strongly than the text just above.

If you continue without following the prescribed process for creating multiple inspections of assets, then you will see something like this in the section/lateral/node grid views - this is what we do not want to see in the data:

...

Duplicate asset IDs.

See now that we have two pipes in the section grid with the same Supplier’s Reference MH1.1. The knock-on affect of this error is that this pipe will never be rendered in WinCan Map because Map does not know which object to draw and will cause all kinds of validation errors.

If we follow the process correctly and create 2 inspections of the asset, then the result in the grid view will look like this:

...

Good inspection management.

Notice that there is now only one asset record (because there is only one pipe in the ground) with a unique asset reference ID (MH1.1), and that in the column on the right there are 2 inspections of this asset.

Now we have created 2 (or more) inspections of an asset each with their own videos, observation codes and photos, we can review the inspections using the inspection list in the centre of the screen here:

...

Inspection selection.

When you click on the the button in the top left of the lower grid view area, you can see the details of all inspections of the currently selected asset. These include:

  • The Job Number (Catchment ID) that the inspection is attached to.

  • The inspection date.

  • The inspection time.

  • The inspection direction.

  • Whether the inspection was completed or abandoned.

Selecting an inspection in this list will take you to the details, video and observations for that inspection.

The default view in WinCan VX for all instances of multiple inspections is that the most recent inspection is always the one that is displayed on screen.

...

Data Validation

...

Marking Objects as ‘Inspected’

...

Quick Assessment Grading

...