Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Problem/Question

...

Table

Meaning

PROJECT

Contains project header data

JOB

Contains data linked to a specific job (usually 1 job/project)

LEG

Contains all legs the pipes sections are assigned to (important for AUSTRIA; leg=Strang!)

SECTION

Contains all pipe sections created within the current project

SECINSP

Contains inspections created per section (usually 1 insp./section)

SECOBS

Contains observations entered per section inspection

SECOBSMM

Contains links to video clips and photos recorded/taken per section observation

NODE

Contains all manholes created within the current project

NODINSP

Contains inspections created per manhole (usually 1 insp./manhole)

NODOBS

Contains observations entered per manhole inspection

NODOBSMM

Contains links to video clips and photos recorded/taken per manhole observation

NODPART

Contains parts (cover, access, chamber, bench) a manhole consists on

NODENTRY

Contains all in- and outlets linked to a manhole

CONTACT

Contains all addresses (i.e. clients, managers, contractors) that may be assigned to the current or future projects

PARTICIPANT

Contains those addresses currently assigned to the project

LOCATION

Contains names of towns and streets entered for the current project

OPERATOR

Contains details to CCTV operators working for the current company

EQUIPMENT

Contains details to CCTV trucks and camera systems used by the current company

...

Table

Field

Meaning

SECTION

OBJ_SortOrder

Section counter: this value is automatically renumbered when sections are deleted

SECTION

OBJ_Key

Section name: this field must contain a unique name to identify the pipe section located between the US and DS manhole

SECTION

OBJ_Length

Length of the whole section in [m] OR [ft]

SECTION

OBJ_Type

Type of pipe line: section (main pipe) or lateral

SECTION

OBJ_City

Name of the city/town

SECTION

OBJ_Street

Name of the street

SECTION

OBJ_FromNode_REF<-Node.OBJ_Key

Name of the US manhole

SECTION

OBJ_ToNode_REF
<- Node.OBJ_Key

Name of the DS manhole

SECTION

OBJ_FromNodeDepth

Depth of the US manhole

SECTION

OBJ_ToNodeDepth

Depth of the DS manhole

SECTION

OBJ_FromNode_REF<-Node.OBJ_NodeType

Type of node/connection: manhole, connection, building

SECTION

OBJ_System

Function of the node: manhole, lamphole, rodding eye etc.

SECTION

OBJ_Situation

Description of the surroundings of the section

SECTION

OBJ_SectionType

Use/purpose of the sewer

SECTION

OBJ_Usage

Type of sewer (storm water, waste water etc.)

SECTION

OBJ_Shape

Shape of the pipe (circle, rectangle, oval)

SECTION

OBJ_Size1

Diameter/height of the pipe; [mm], [inch]

SECTION

OBJ_Size2

Width of the pipe; [mm], [inch]

SECTION

OBJ_Material

List of different pipe materials

SECTION

OBJ_ConstructionDate

Year of construction

SECTION

OBJ_Memo

General remark to the section

SECINSP

SI_InspName

Name/Number of the survey (will mostly be set automatically). This field must NEVER be empty

SECINSP

INS_Operator_REF
<- Operator.OP_Key

Link to the operator name

SECINSP

INS_Equipment_REF
<- Equipment.EQ_Key

Link to the list of the vehicles used for section surveys

SECINSP

INS_Camera_REF
<- Equipment.EQ_Key

Link to the list of the cameras used for section surveys

SECINSP

INS_StartDate

Date of the beginning of the inspection

SECINSP

INS_StartTime

Time of the inspection beginning

SECINSP

INS_EndTime

Time of the inspection termination

SECINSP

INS_InspectionDir

Inspection direction (WITH or AGAINST the flow). This field must NEVER be empty

SECINSP

INS_PhotoRef

DVD N°: value automatically set for every section during a ViewerExport. Important for creation of a DVD box cover

SECINSP

INS_Cleaned

Pipe section previously cleaned: YES / NO

SECINSP

INS_Weather

Weather conditions during the inspection

SECINSP

INS_Method

Camera technology: crawler, push camera etc.

SECINSP

INS_Purpose

Reason of inspection: general survey, rehab. survey

SECINSP

INS_PhotoRef

N° of storage medium set autom. during data distrib.

SECINSP

INS_Memo

General remark to the survey

SECOBS

OBS_SortOrder

Observation counter: this value is automatically renumbered when observations are deleted

SECOBS

OBS_Distance

Observation site measured from inspection start node

SECOBS

OBS_DistanceToGo

Observation site measured from inspection end node

SECOBS

OBS_Observation

Entry of observation text via country specific damage catalogues for sections (double click)

SECOBS

OBS_RateValue

Entry of damage grades

SECOBS

OBS_GradeS

Calculation of structural damage grades

SECOBS

OBS_GradeO

Calculation of operational/service damage grades

SECOBS

V_OBS_Picture1

Taking the 1st picture of an observation (double click)

SECOBS

V_OBS_Picture2

Taking the 2nd picture of an observation (double click)

SECOBS

V_OBS_Clip

Recording of video clip(s) of the current section (double click)

SECOBS

OBS_LateralSection_REF

Recording of satellite sections (lateral sections) linked to the current main section (double click)

SECOBS

OBS_TimeCtr

Displaying the MPEG timecode of the current observation

SECOBS

V_OBS_Scan

Import data from a pipe scan (DigiSewer, Panoramo, RPP) and launch the ScanExplorer module

SECOBS

V_OBS_LaserScan

Run the LaserScan module for pipe deformation measurement (RingLaser, MultiLaser)

SECOBS

OBS_Memo

Special remark to the current observation

NODE

OBJ_Key

The values entered into the section fields OBJ_FromNod_REF or OBJ_ToNode_REF are automatically transferred into this field

NODE

OBJ_City

Name of the city/town

NODE

OBJ_Street

Name of the street

NODE

OBJ_Situation

Situation of the manhole

NODE

OBJ_DepthToInvert

Depth of the manhole in [m] or [ft]

NODE

OBJ_Point_REF

Altitude of the manhole cover ([m]/[ft] above sea level

NODE

OBJ_NodeType

Type of the node/connection: manhole, connection point, building

NODE

V_OBJ_Shape_WKT_X

X-coordinate of the manhole (used in MAP and 3D)

NODE

V_OBJ_Shape_WKT_Y

Y-coordinate of the manhole (used in MAP and 3D)

NODE

V_OBJ_Shape_WKT_Z

Z-coordinate of the manhole (i.e. cover altitude, used in 3D)

NODINSP

INS_StartDate

Date of the manhole survey

NODINSP

INS_StartTime

Start time of the manhole survey

NODINSP

INS_EndTime

End time of the manhole survey

NODINSP

INS_RadialRef

Horizontal reference point for setting the clock position of the in- and outlets

NODPART

NOP_Type

Description of the manhole part:
cover, shaft, cone (taper), chamber, bench, channel

NODPART

NOP_InsertType

Cone type: conical centered, conical off centered…

NODPART

NOP_Shape

Shape: cover, shaft, chamber

NODPART

NOP_Size1

Diameter/Length: cover, shaft, chamber

NODPART

NOP_Size2

Width: cover, shaft, chamber

NODPART

NOP_DepthToHeight

Height: cover (“thickness”), shaft, cone, chamber

NODPART

NOP_Height

Thickness: cover, top rings

NODPART

NOP_Material

Material: cover, shaft, cone, chamber

NODOBS

OBS_Observation

Entry of observation text via country specific damage catalogues for manholes (double click)

NODOBS

V_OBS_Picture1

Taking the 1st manhole picture

NODOBS

V_OBS_Picture2

Taking the 2nd manhole picture

NODOBS

V_OBS_Clip

Recording of video clip(s) for the current manhole

NODOBS

V_OBS_Scan

Import data from a manhole scan and launch the ScanExplorer module