Back to WinCan VX DDMS User Guide
Sections
Page Contents
WinCan VX Section Header
The WinCan VX section (and lateral) header is quite different from the WRc versions due to the fact that this is a different inspection standard, but there are some similarities because both standards follow the guidelines laid out in BS EN 13508.
The WinCan section and node headers are split into two sides, left and right in all standards for all territories around the world. The difference between the two sides is that the left side is all about the asset and the right side is all about the inspection. In this page, we will consider the asset details and then the inspection details.
In this section we will look in detail at the section header, but not the node header. The node header is vitally important in HADDMS projects and cannot be ignored, but the general theme of the fields follows the section header and many of the fields only have simple Yes/No option lists so do not really need any detailed explanation.
In the WinCan VX headers there is a consistent colour coding to the field captions:
Grey – a regular data entry field.
Blue – a WinCan field that is not needed by the standard but is either needed by the software for data management or is a ‘nice to have’ data field in the reporting.
Green – a field that WinCan VX takes care of for you. You can of course overwrite the data in the field at any time, but for now you don’t need to worry about it and it will be taken care of in the background as you work through the inspections.
Yellow (or whatever colour is defined in the User Settings) – a mandatory data field that can be mandatory if;
WinCan VX cannot function correctly without it, or
leaving it blank will lead to a critical upload error with the shapefiles going into HADDMS.
Info – there are some fields that are conditionally mandatory by HADDMS like the ‘Connected Continuous Item’ (SUPP_CON) in the node header which is mandatory when the ‘Node Type’ (ITEM_TY_CO) is ‘CN’. There are no special colours for these fields, but the validator will detect them as critical errors when they are left blank.
Open a new blank section header and you will see the following fields split into left and right hand sides as described below.
Note – hovering your mouse pointer over the cation of a field will display the ‘tip-text’ for that field which will help to explain what this field refers to and also which HADDMS data field it refers to.
Where relevant, we have included the HADDMS shapefile that this WinCan field maps to and from using the format [Shapefile].[Field Name]
Section Attribute Header
Section
This is nothing more than a numeric counter inside the WinCan database for the asset which starts at 1 and increments with each asset added to the database.
Asset Style
This a very important field for WinCan that cannot be empty. It describes whether the WinCan object is a Section, Lateral or Surface item (or Drainage Asset, Connector Node or Region Item in the Nodes grid) as is described in the section Understanding Object Types.
Inspection Status
his is a pseudo-HADDMS field that sits in limbo between the HADDMS data and the internal requirements of WinCan VX. It is the field that has been described already in the section WinCan VX Project Setup and although it has no direct value in the HADDMS data fields, it does have a significant effect on the scoring values produced by WinCan VX so that they match with the HADDMS scoring results. Under the normal scoring of pipes, structural and service inspection grades are assigned values form 1 to 5 in a similar (but not identical) way to WRc projects, but in HADDMS data there are two additional grades – 0 for where the asset has not been attempted and 9 for where the inspection was attempted but was not successful. So, good use of this field will drive good scoring results.
Section
This is nothing more than a numeric counter inside the WinCan database.
Asset Style
This a very important field for WinCan that cannot be empty. It describes whether the WinCan object is a Section, Lateral or Surface item as is described in the section Understanding Object Types.
Inspection Status
This is a pseudo-HADDMS field that sits in limbo between the HADDMS data and the internal requirements of WinCan VX. It is the field that has been described already in the section WinCan VX Project Setup and although it has no direct value in the HADDMS data fields, it does have a significant effect on the scoring values produced by WinCan VX so that they match with the HADDMS scoring results. Under the normal scoring of pipes, structural and service inspection grades are assigned values form 1 to 5 in a similar (but not identical) way to WRc projects, but in HADDMS data there are two additional grades – 0 for where the asset has not been attempted and 9 for where the inspection was attempted but was not successful. So, good use of this field will drive good scoring results.
PLR Suffix
This also is not a HADDMS required field, but follows exactly the same logic as the PLR Suffix field in WRc inspection data albeit with different values. In the HADDMS setup, the default value is ‘.1’ so after you create a pipe with upstream node CP1 and downstream node CP2 then the Supplier’s Reference for the field will be automatically created by the software as CP1.1 which is the extremely important ID of the asset. You should use increasing values of ‘.2’, ‘.3’ etc to describe multiple lines between similar assets in the same way they you do with X, Y, Z etc in WRc projects. This does not apply to node assets. Maximum 2 characters.
Supplier’s Reference
continuous.SUPP_REF
In Sections, Laterals and Surface items it is concatenated from the upstream node SUPP_REF and the PLR Suffix at all times by the software as described in the previous section. Maximum 52 characters (50 characters for the Upstream Node ID plus 2 for the PLR Suffix).
DDMS Reference
continuous.PIPE_REFER
This is the ID of the continuous item on the HADDMS database. The field in WinCan VX is read-only because of the round-tripping principles. It does not matter what you decide to change the Supplier’s Reference to during your processing work, but if the DDMS Reference exists already on the system, then it must remain as it is. You will notice that when you create a new ‘uncharted’ asset that this field is blank and remains read-only, and also for the two nodes that are connected to the object. This is how HADDMS identifies uncharted assets, because the incoming data on upload has a SUPP_REF field value but it does not have an PIPE_REFER value, and as a result HADMMS automatically creates the PIPE_REFER on upload.
Total Length [m]
continuous.LENGTH
This is the full length of the continuous item from end to end along its geometric shape in metres to 3 decimal places.
Town or Village
continuous.LOC_TOWN
Is a free-text field where you can add free text information. Maximum 50 characters.
Road Name
continuous.LOC_ST
Is a free-text field where you can add free text information. Maximum 50 characters.
Location
continuous.LOC_TYP_CO
This data field defines where the asset is located.
Warning - care should be taken by operators here because it is common to make mistakes like assigning the value ‘Left Verge’ to a pipe where it actually crosses the carriageway. The common mistake that people make here is that they think of where they are standing and the location of the manhole that they are inspecting from and enter this data but in reality, this field refers to the location of the pipe and not the manhole.
Upstream Node
continuous.SUPP_REFUP
This is the SUPP_REF of the upstream node. Maximum 50 characters.
Upstream DDMS Node
point/region.ASSET_REF
Is read only because it is the HADDMS reference of the upstream node and is defined in the node data.
Upstream Node Type
point/region.ITEM_TY_CO
Is the Node Type of the upstream asset.
Upstream Pipe Depth [m]
continuous.UPSTR_DEPT
Is the depth of the pipe from the cover level at the upstream end. Up to 3 decimal places.
Warning – this is often incorrectly measured on site as the depth of the manhole. This is a pipe inspection, not a node inspection where the depth of the pipe and the depth of the node are two very different things, particularly where the chamber is a catchpit or a backdrop exists (always take the depth of the top rodding eye of the backdrop, not the lower exit point). Unit of measurement is metres, as defined in the caption.
Upstream Pipe Invert Level [m]
continuous.UPSTR_INVE
This is the height above sea level for the continuous item at the upstream end. This is not something that the CCTV operator usually needs to worry about and for this reason, the field is hidden from view when the user is logged into WinCan VX as an Operator and is only visible to users logged in to the application as Admin.
Info for data processors – there is button in the Tools ribbon bar called ‘Calculate Invert Levels’ which will auto populate this field when the chamber cover level is defined in the node data and the pipe depth is defined in the section data.
For this reason, it is not a good idea for operators to enter zero when the level is not known. It is better to simply leave it blank and then the ‘Calculate Invert Levels’ tool will skip the calculation for this asset because it has no validity.
Downstream Node
continuous.SUPP_REFDN
Similar to Upstream Node, but for the downstream end.
Downstream DDMS Node
point/region.ASSET_REF
Similar to Upstream DDMS Node, but for the downstream end.
Downstream Node Type
point/region.ITEM_TY_CO
Similar to Upstream Node Type, but for the downstream end.
Downstream Pipe Depth [m]
continuous.DNSTR_DEPT
Similar to Upstream Pipe Depth [m], but for the downstream end. Up to 3 decimal places.
Downstream Pipe Invert Level [m]
continuous.DNSTR_INVE
Similar to Upstream Pipe Depth [m], but for the downstream end. Up to 3 decimal places.
Connectivity Certainty
continuous.CERT_CONN
This field has a simple Yes/No pick list option and is mandatory because it is a critical error on upload to the HADDMS database if it does not have a value. The field is used to describe if the connectivity between the upstream and downstream nodes in this continuous item can be confirmed.
Flow Direction Certainty
continuous.FLOW_DIR
This field has a simple Yes/No pick list option and is mandatory because it is a critical error on upload to the HADDMS database if it does not have a value. The field is used to describe if the flow direction between the upstream and downstream nodes in this continuous item can be confirmed.
Info - his may sound easy, but becomes more difficult in situations like where there is a culvert under the road with no visible flow, so how can you tell which is the upstream end and the downstream end of the asset. There are times when this needs to be confirmed by the office processing and cannot be deduced on site.
Asset Ownership
continuous.OWNER
Under most circumstances this will be ‘Highway Authority’ but there may be special cases where this is not the case.
Use
continuous.SYSTEM_TYP
The use of the continuous asset.
Info - WinCan VX places a default value of ‘Surface Water’ into this field for all newly created assets because it is rare for HADDMS inspections to be of foul sewers, but not impossible. Where trunk roads go through cities or built up areas, there can be foul sewers that run under the road and need to be inspected even though they are the responsibility of the water company.
Type of Asset
continuous.ITEM_TY_CO
This is a mandatory field, again because HADDMS throws a critical error if it is left blank. There are a number of validation rules in WinCan VX that refer to the logical use of this field. Example include if the ‘Type of Asset’ is ‘Pipework’ then the material is unlikely to be ‘Gabions’.
Porous
continuous.POROUS
Again, a simple Yes/No option pick list. Refers to whether or not the pipe material is porous.
Info - this can be extremely hard to assess during CCTV inspection and should not be confused with ‘Perforated’.
Perforated
continuous.PERFORATED
Another simple Yes/No option pick list. This should be entered as ‘Yes’ if you can clearly see perforation holes in the pipe. If they are there, then they are usually evenly spaced and all around the pipe, and their purpose is to allow the water to drain away to the surrounding ground when it rains. This is normall an easy field for CCTV operators to complete.
Section Inspection Header
Inspection
This is a numeric counter inside the WinCan database for the asset inspection which starts at 1 and increments with each inspection added to the asset.
Back to WinCan VX DDMS User Guide