Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 6 Next »

Back to Working with Inclination Data

Sections

The selected root page could not be found.

Review the Results in WinCan VX

Now that we have completed an inclination test on site with the CCTV truck, let’s inspect the data and see what the graphs look like.

In this example, we will first consider the basic data about the pipe that has been entered into the section header. The inspection direction is downstream and the pipe full length from end to end is 23.00m. Then there is the altitude data, which looks like this:

Analysis1

Altitude data for the worked example.

Here, we can see:

  • The ID of the upstream and downstream node

  • The depth of the pipe at the upstream and downstream ends of the pipe. Notice that the value of depth at the downstream end is is less than that at the upstream end. Does this mean that the pipe is going uphill? No, read on.

  • The upstream and downstream end invert levels which is the height above sea level for the ends of the pipe. Notice that the height above sea level is lower at the downstream end than it is at the upstream end, so this is how we know that the pipe is flowing downhill and the difference in height from one end to the other is 121.626 - 121.403 = 0.223m or 223mm

So, how is the depth of the pipe at the downstream end so much less than the depth of the pipe at the upstream end? This is because the ground is not level, and demonstrates the point that you can never use the pipe depths to establish if the pipe is flowing the correct way. The only way to prove this is by considering and calculating the altitudes of the ends of the pipe above sea level.

Understanding altitudes and depths.

This would normally be done by measuring the altitude of the cover level above seas level using GPS equipment, then measuring the depth of the pipe at each end with a tape measure, entering these values into WinCan VX, and then using the ‘Calculate Invert Levels’ tool in the ‘Tools’ ribbon to do the subtraction without user error.

It should always be remembered that drains seldom have a very large gradient except in exceptional circumstances and surface water pipes usually have an even smaller gradient than foul water pipes. This is why when you see matching pairs of manholes side-by-side where one is foul and the other surface, the surface water pipes are usually large diameter and shallow, and the foul water pipes are small diameter and deep.

Because of this, a high level of accuracy is needed with the vertical confidence on GPS equipment, because even a few millimetres error can have damaging effects on the results.

Print the Reports in WinCan VX