Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

This article explain what has to be considered while recoding video to use with the laserscanexplains how the operator must proceed to properly record a video clip with the ring laser equipment.
The end part describes how to position the calibration rings or the calibration points.
For maore more details please read the Laserscan manual to the module LaserScsan.

Instructions

Range of operation
• Investigation of pipe line systems, which have to satisfy
high demands on material stability.
– Hydropower plants (stability examination of high
pressure pipes)
• Warranty assessment of high performance drainage
systems for objects like…
– Tunnels and bridges
– Highways
– Airport Runways

Prior to the survey

• Pipe cleaning: removal of floating deposits
• Removal of encrustations to reduce light reflexions on
pipe wall or pipe ground
• Block water flow in order to get the pipe ground visible

Run the survey

...

Prior to the scan
• Center camera head
• Set Laser ring diameter to 75% of image height
• Set recording format to MPEG2 in order to increase
accuracy of measuring results
• Place the whole length of the calibration bar within the
camera view angle
• Cover the manhole in order to avoid light intrusion at the
beginning of recording a video clip

During the scan
• Switch off the light and text display: only the laser ring
must be visible
• Increase the light intensity of the laser ring at larger
diameters accordingly
• Decrease image luminosity in order to get disturbing red
sparks disappeared
• Scan with a constant low speed (max. 17 cm/sec) in
order to avoid jerky movements of the camera head.
• Keep the camera head centered during recording
• Record a sequence showing the entire calibration bar
(100 mm - 600 mm)

Center the camera

...

Scan procedure

...

Speed <= 17 cm/sec

...


Record calibration bar (vertical)

...

Calibration bar:
scale invisible

...

Calibration bar:
scale visible

...

Laser ring with light intrusion

...

Settings: OK

...

Set calibration points

...

Show calibration rings

...

After the scan

...

Multi-Laser; scan pipe deformation

...

Multi-Laser; measure pipe deformation

...

 

Info

You

...

always need a video clip with

...

the corresponding index file

...

Filter by label (Content by label)
showLabelsfalse
max5
spacescom.atlassian.confluence.content.render.xhtml.model.resource.identifiers.SpaceResourceIdentifier@10ef6
showSpacefalse
sortmodified
typepage
reversetrue
labelsDeformation Laserscan Ringlaser
cqllabel in ( "laserscan" , "ringlaser" , "deformation" ) and type = "page" and space = "FAQ"

...

hiddentrue

...

(time-distance file); without this the LaserScan module cannot run the scan process.

Related articles: