Instructions

Range of operation
• Investigation of pipe line systems, which have to satisfy high demands on material stability.
– Hydropower plants (stability examination of high pressure pipes)
• Warranty assessment of high performance drainage systems for objects like…
– Tunnels and bridges
– Highways
– Airport Runways

Prior to the survey

• Pipe cleaning: removal of floating deposits
• Removal of encrustations to reduce light reflexions on pipe wall or pipe ground
• Block water flow in order to get the pipe ground visible

Run the survey

 

Prior to the scan
• Center camera head
• Set Laser ring diameter to 75% of image height
• Set recording format to MPEG2 in order to increase accuracy of measuring results
• Place the whole length of the calibration bar within the camera view angle
• Cover the manhole in order to avoid light intrusion at the beginning of recording a video clip

During the scan
• Switch off the light and text display: only the laser ring must be visible
• Increase the light intensity of the laser ring at larger diameters accordingly
• Decrease image luminosity in order to get disturbing red sparks disappeared
• Scan with a constant low speed (max. 17 cm/sec) in order to avoid jerky movements of the camera head.
• Keep the camera head centered during recording
• Record a sequence showing the entire calibration bar (100 mm - 600 mm)

Center the camera

Scan procedure

Speed <= 17 cm/sec

 

Record calibration bar (horizontal)


Record calibration bar (vertical)

Calibration bar: scale invisible

Calibration bar: scale visible

Laser ring with light intrusion

Laser ring with light reflections


Laser ring too big

Laser light too weak

Laser ring not centered

Water flow not blocked

Settings: OK

Set calibration points

Show calibration rings

After the scan

 

Multi-Laser; scan pipe deformation

Multi-Laser; measure pipe deformation

 

You always need a video clip with the corresponding index file (time-distance file); without this the LaserScan module cannot run the scan process.