WinCan Map: Field mapping
Before GIS-data can be transferred into WinCanVX, each GIS field needs to be mapped or assigned manually to the corresponding WinCan field.
This article describes which field mappings have to be created so sections and manholes can be transfered to from WinCan Map to WinCan VX.
Instructions
Step-by-step instructions
Select WinCan Map Feldzuordnung bearbeiten auswählen.
Edit WinCan mapping
Â
The most important section/manhole fields are listed below..
OBJ_Key | Section/Manhole Name (unique name to identify the section/manhole) |
OBJ_Length | Length of the section (distance from Upstream Manhole to Downstream Manhole) |
nodeFromKey | Name of the Upstream Manhole |
nodeToKey | Name of the Downstream Manhole |
OBJ_DepthToInvert | Depth of the manhole (distance from cover to bench/channel) |
OBJ_City | Name of the City/Town where the section/manhole is located |
OBJ_Street | Name of the Street where the section/manhole is located |
OBJ_Shape | Shape of the pipe (circular, rectangular, egg-shaped etc.) |
OBJ_Size1 | Diameter/Height of the pipe [mm] / [inch] |
OBJ_Size2 | Width of the pipe [mm] / [inch] |
OBJ_Material | Material of the pipe (concrete, steel etc.) |
OBJ_SectionType | Type of section (waste water, stormwater, mixed water) |
OBJ_Usage | Type of section (replaces OBJ_SectionType in some standards) |
OBJ_WasteWaterType | Type of section (replaces OBJ_SectionType in some standards) |
Â
The field OBJ_Key is mandatory