Rausch Mobile Pro; basic configuration

Question/Problem:

What must be checked in order to get the equipment Mobile PRO from the company RAUSCH fully operated from WinCanVX (i.e. LiveVideo and control unit)?

Answer/Solution:

1.) Open the folder C:\RauschTV\PipeCommander (default folder containing software tools from RAUSCH)

2.) Copy the file VTG2GCOM_V2_17_7_91_Rausch.dll
from C:\RauschTV\PipeCommander into C:\ProgramFiles (x86)\CDLAB\Assemblies

3.) Delete the existing file VTG2GCOM.dll

4.) Rename the file VTG2GCOM_V2_17_7_91_Rausch -> VTG2GCOM.dll

5.) Copy the file mid2253.dll
from C:\RauschTV\PipeCommander into C:\ProgramFiles (x86)\CDLAB\Assemblies

6.) Open WinCanVX, go to Home > Settings > OSD and select the device PS-VTG2:

7.) Hit the button Test in order to test the communication between the OSD-device and the computer (RED = communication failed; GREEN = communication successful)

8.) Click on the gear icon right to the selected device entry and check the settings needed as described on the next page…

9.) Hit the tab Offline and check the option Rausch equipment:

10.) Hit the tab Other and select one the COM-Ports the operating systems currently provides: